Sample aluminum and bimetal heating radiator models testing results (July 2016)

 

Aluminum section radiators  (axle spacing 500 mm)
Name of sample (model) Weight of section

declared/actual, kg

Heat transfer of  section declared/actual, W Conformity to the GOST impermeability requirements Conformity to the GOST

static durability  requirements

Testing laboratory
Ogint Delta Plus 500, section aluminum radiator 0.81/0.85

+4.94%

180/120

-33.3%

Conforming Conforming

 

Scientific-technical company Vitaterm OOO
Lammin ECO AL500-80, section aluminum radiator 0.85/0.82

-2.35%

190/128

-36.63%

Conforming Conforming

 

Scientific-technical company Vitaterm OOO
Aquaprom 500A, section aluminum radiator 0.84/0.91

+8.33

180/135

-25%

Conforming Conforming Scientific-technical company Vitaterm OOO
MONLAN 500/70, section aluminum radiator 0.8/0.67

-16.25%

166/127

-23.49%

Conforming Conforming Scientific-technical center Santekhprom AO
RISPA Optima 500-80,

section aluminum radiator

0.95/0.78

-17.89%

180/140

-22.22%

Conforming Nonconforming Scientific-technical center Santekhprom AO
TEPLADA Lux 70,

section aluminum radiator

0.85/0.67

-21.18%

175/138

-21.14%

Conforming Nonconforming Scientific-technical center Santekhprom AO
BIPLUS LUNE 500L,

section aluminum radiator

0.85/0.83

-2.35%

170/135

-20.59%

Conforming Conforming Scientific-technical center Santekhprom AO
Teplomir 500/96, section aluminum radiator 1.18/1.11

-5.08%

195/155

-20.51%

Conforming Conforming

 

Scientific-technical company Vitaterm OOO
Rommer Profi 500,

section aluminum radiator

1.0/0.89

-11%

166/147

-11.45%

Conforming Conforming Scientific-technical center Santekhprom AO
ORANA 500,

section aluminum radiator

1.15/1.0

-13.04%

155/155

0%

Conforming Conforming Scientific-technical center Santekhprom AO
Bimetal section radiators (axle spacing 500 mm)
Name of sample (model) Weight of section

declared/actual, kg

Heat transfer of  section declared/actual, W Conformity to the GOST impermeability requirements Conformity to the GOST

static durability  requirements

Testing laboratory
FIRENZE FH Grand Bi500-80, section bimetal radiator Not available/ 1.24

—–

180/133

-26.11%

Conforming Conforming Scientific-technical center Santekhprom AO
Termohit B 500/80, section bimetal radiator 1.65/1.62

-1.82%

190/142

-25.26%

Conforming Conforming Scientific-technical company Vitaterm OOO
Lammin Eco BM500-80,

bimetal section radiator

1.45/1.28

-11.72%

180/142

-21.11%

Nonconforming Nonconforming Scientific-technical center Santekhprom AO
Germanium NEO bm500,

section bimetal radiator

1.32/1.27

-3.79%

175/140

20%

Conforming Conforming Scientific-technical center Santekhprom AO
ROMMER BI 500-80-150, section bimetal radiator 1.56/1.51

-3.36%

175/143

-18.29%

Conforming Conforming Scientific-technical company Vitaterm OOO
OASIS 500/70,

section bimetal radiator

1.25/1.06

-15.2%

146/124

-15.07%

Conforming Conforming Scientific-technical center Santekhprom AO
Blyss 500/80, section bimetal radiator 1.43/1.6

+11.89%

165/141

-14.55%

Conforming Conforming Scientific-technical company Vitaterm OOO